Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Transbound Emerg Dis ; 69(4): e823-e830, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34706153

RESUMO

Since the start of the coronavirus disease of 2019 (COVID-19) pandemic, several episodes of human-to-animal severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) transmission have been described in different countries. The role of pets, especially domestic dogs, in the COVID-19 epidemiology is highly questionable and needs further investigation. In this study, we report a case of COVID-19 in a French dog living in close contact with its owners who were COVID-19 patients. The dog presented rhinitis and was sampled 1 week after its owners (a man and a woman) were tested positive for COVID-19. The nasal swabs for the dog tested remained positive for SARS-CoV-2 by reverse transcription quantitative real-time PCR (RT-qPCR) 1 month following the first diagnosis. Specific anti-SARS-CoV-2 antibodies were detectable 12 days after the first diagnosis and persisted for at least 5 months as tested using enzyme-linked immunoassay (ELISA) and automated western blotting. The whole-genome sequences from the dog and its owners were 99%-100% identical (with the man and the woman's sequences, respectively) and matched the B.1.160 variant of concern (Marseille-4 variant), the most widespread in France at the time the dog was infected. This study documents the first detection of B.1.160 in pets (a dog) in France, and the first canine genome recovery of the B.1.160 variant of global concern. Moreover, given the enhanced infectivity and transmissibility of the Marseille-4 variant for humans, this case also highlights the risk that pets may potentially play a significant role in SARS-CoV-2 outbreaks and may transmit the infection to humans. We have evidence of human-to-dog transmission of the Marseille-4 variant since the owners were first to be infected. Finally, owners and veterinarians must be vigilent for canine COVID-19 when dogs are presented with respiratory clinical signs.


Assuntos
COVID-19 , Doenças do Cão , Animais , Anticorpos Antivirais , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/veterinária , Doenças do Cão/diagnóstico , Doenças do Cão/epidemiologia , Cães , Feminino , Humanos , Pandemias/veterinária , Reação em Cadeia da Polimerase em Tempo Real/veterinária , SARS-CoV-2/genética
2.
Vet Comp Orthop Traumatol ; 32(6): 475-482, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31357218

RESUMO

OBJECTIVE: The aim of this study was to prospectively evaluate postoperative alignment when using fracture reduction under the plate (FRUP) during a minimally invasive plate osteosynthesis in tibial and femoral fractures, without intraoperative imaging, and report immediate postoperative complications. MATERIALS AND METHODS: After precise plate contouring and preoperative planning, FRUP was obtained with one cortical screw per fragment. Fractures were stabilized with a plate or plate rod. Tibial/femoral lengths, tibial plateau angles, mechanical medial proximal and distal tibial angles, anatomical lateral distal femoral angles, femoral curvatum and neck anteversion were evaluated on postoperative radiographs and contralateral bone. Tibial torsion was evaluated visually. Paired t-test were used to compare data. Immediate postoperative complications were recorded. RESULTS: Twenty-one tibial and 20 femoral fractures were stabilized (14 plate rod cases). Mean postoperative operated tibial length was 1.4% shorter (p = 0.001). Mean postoperative operated femoral length was 2% shorter (p = 0.04). Mean operated tibial plateau angle was 1.1° lower (p = 0.02). No difference in tibial torsion was noticed. No significant difference in mechanical medial proximal tibial angle, mechanical medial distal tibial angle, anatomical lateral distal femoral angle and femoral neck anteversion was observed. Mean operated femoral curvatum angle was 5.6° less (p = 0.01). Five cases (3 plate rod cases) required an immediate revision. CLINICAL SIGNIFICANCE: Minimally invasive plate osteosynthesis with FRUP leads to acceptable postoperative alignment. Correct pin placement should be evaluated.


Assuntos
Placas Ósseas/veterinária , Doenças do Gato/cirurgia , Doenças do Cão/cirurgia , Fraturas do Fêmur/veterinária , Fraturas Ósseas/veterinária , Fraturas da Tíbia/veterinária , Animais , Doenças do Gato/diagnóstico por imagem , Gatos/lesões , Diáfises/lesões , Doenças do Cão/diagnóstico por imagem , Cães/lesões , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/veterinária , Estudos Prospectivos , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
3.
J Am Anim Hosp Assoc ; 53(5): 270-276, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28792798

RESUMO

A 4 mo old spayed female golden retriever was presented with a peritoneopericardial diaphragmatic hernia (PPDH) that was diagnosed during neutering. Echocardiography revealed a fluid-filled structure and parts of the liver in the pericardial cavity. Computed tomography confirmed the existence of the PPDH and the herniation of the right medial liver lobe and the gallbladder. Cystic masses were observed in the pericardial and the peritoneal cavities, possibly communicating through the PPDH. A median laparotomy revealed a single lobulated cystic lesion extending into both the pericardial and peritoneal cavities through the PPDH. Because of the nonviable aspect of some parts of the liver parenchyma, the gallbladder was dissected from the fossa, and the central division of the liver was resected. A cholecystopexy was performed on the diaphragm to limit gallbladder mobility. The PPDH was closed in the standard fashion. Histopathology of the cystic structure was compatible with a pericardial pseudocyst. Two months postoperatively, the dog was healthy, and the results of blood biochemistry and abdominal ultrasonography were normal. A pericardial pseudocyst can be associated with a PPDH in young dogs. Moreover, cholecystopexy appears to be a safe and effective method of limiting gallbladder mobility after resection of the central hepatic division.


Assuntos
Doenças do Cão/cirurgia , Vesícula Biliar/cirurgia , Hérnias Diafragmáticas Congênitas/veterinária , Cisto Mediastínico/veterinária , Animais , Procedimentos Cirúrgicos do Sistema Biliar/veterinária , Diafragma , Cães , Feminino , Hérnias Diafragmáticas Congênitas/cirurgia , Cisto Mediastínico/cirurgia , Pericárdio
4.
Vet Surg ; 43(3): 271-81, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24467692

RESUMO

OBJECTIVE: To compare clinical outcome and callus biomechanical properties of a novel angle stable interlocking nail (AS-ILN) and a 6 mm bolted standard ILN (ILN6b) in a canine tibial fracture model. STUDY DESIGN: Experimental in vivo study. ANIMALS: Purpose-bred hounds (n = 11). METHODS: A 5 mm mid-diaphyseal tibial ostectomy was stabilized with an AS-ILN (n = 6) or an ILN6b (n = 5). Orthopedic examinations and radiographs were performed every other week until clinical union (18 weeks). Paired tibiae were tested in torsion until failure. Callus torsional strength and toughness were statistically compared and failure mode described. Total and cortical callus volumes were computed and statistically compared from CT slices of the original ostectomy gap. Statistical significance was set at P < .05 RESULTS: From 4 to 8 weeks, lameness was less pronounced in AS-ILN than ILN6b dogs (P < .05). Clinical union was reached in all AS-ILN dogs by 10 weeks and in 3/5 ILN6b dogs at 18 weeks. Callus mechanical properties were significantly greater in AS-ILN than ILN6b specimens by 77% (failure torque) and 166% (toughness). Failure occurred by acute spiral (control and AS-ILN) or progressive transverse fractures (ILN6b). Cortical callus volume was 111% greater in AS-ILN than ILN6b specimens (P < .05). CONCLUSIONS: Earlier functional recovery, callus strength and remodeling suggest that the AS-ILN provides a postoperative biomechanical environment more conducive to bone healing than a comparable standard ILN.


Assuntos
Pinos Ortopédicos/veterinária , Cães/lesões , Tíbia/patologia , Fraturas da Tíbia/veterinária , Animais , Fenômenos Biomecânicos , Remodelação Óssea , Calo Ósseo/fisiologia , Cães/cirurgia , Desenho de Equipamento/veterinária , Consolidação da Fratura , Coxeadura Animal/fisiopatologia , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia
5.
J Am Vet Med Assoc ; 238(1): 89-93, 2011 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-21194327

RESUMO

OBJECTIVE: To evaluate the long-term prognosis of cats with a congenital extrahepatic portosystemic shunt (CEPSS) attenuated through gradual occlusion with cellophane banding (CB). DESIGN: Retrospective case series. ANIMALS: 9 cats with a CEPSS that was attenuated with CB. PROCEDURES: Medical records of cats surgically treated for CEPSS by means of CB from January 2000 through March 2007 were reviewed. Extracted data included preoperative clinical signs, medications, diagnostic results including serum bile acids concentrations, surgical technique, intraoperative and postoperative complications, and long-term follow-up information. RESULTS: 2 cats that developed refractory seizures were euthanized within 3 days after the CB procedure. Seven of the 9 cats survived to 15 days after surgery. Four cats did not have any clinical signs of CEPSS at long-term follow up. At that time, 5 cats had a postprandial SBA concentration within reference limits and 1 cat had persistent ptyalism. One cat had biurate ammonium stones removed > 2 years after surgery. One cat was euthanized 105 days after surgery because of uncontrolled seizures. The 3-year survival rate was 66%. CONCLUSIONS AND CLINICAL RELEVANCE: Uncontrolled seizure activity was the most common cause of death after CB. Long-term outcome for cats with CEPSS was fair to good after the procedure. Cats with a CEPSS surviving the immediate postoperative period had a fair to good long-term outcome. Cellophane banding without intraoperative attenuation appears to be an acceptable technique for gradual occlusion of a CEPSS in cats. Cats should be monitored closely for development of neurologic disorders in the postoperative period.


Assuntos
Doenças do Gato/congênito , Celofane , Hipertensão Portal/veterinária , Sistema Porta/anormalidades , Animais , Doenças do Gato/cirurgia , Gatos , Feminino , Hipertensão Portal/congênito , Hipertensão Portal/cirurgia , Masculino , Sistema Porta/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
6.
Vet Surg ; 38(7): 881-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19781032

RESUMO

OBJECTIVE: To investigate the effect of fracture configuration on the mechanical properties of standard interlocking nails (ILNs) and a novel angle-stable ILN (ILNn) in bending. STUDY DESIGN: In vitro experimental study. SAMPLE POPULATION: Synthetic tibial gap fracture bone models. METHODS: Bone models, featuring a 5 or 120 mm central defect, respectively, mimicking a simple diaphyseal and a comminuted fracture involving both metaphyses, were implanted with 6 or 8 mm screwed or bolted standard ILNs (ILN6s, ILN6b, ILN8s, ILN8b, respectively) or an ILNn. Specimens were tested in 4-point bending. Construct angular deformation (AD) and slack were statistically compared (P<.05). RESULTS: With increasing gap size, standard ILN construct AD increased significantly by approximately 27% in ILN8b and by up to 105% in ILN6s. Similarly, standard ILN construct slack significantly increased by approximately 33% in ILN8b (from approximately 4.2 degrees to approximately 5.6 degrees) and by up to approximately 130% in ILN6s (from approximately 7 degrees to approximately 16 degrees). Conversely, there was no difference in the ILNn construct AD (approximately 4 degrees) regardless of gap size. ILNn AD was the lowest of all groups and occurred without slack. CONCLUSIONS: This study demonstrated that the angle-stable ILNn provided construct stability regardless of fracture configuration, whereas the intrinsic slack of standard ILNs could jeopardize construct stability in a fracture configuration involving the metaphyses. CLINICAL RELEVANCE: Use of standard ILNs may be optimal in diaphyseal fractures where circumferential nail/cortical contact could augment repair stability. Conversely, the angle-stable ILNn may represent a reliable fracture stabilization method for diaphyseal fractures as well as fractures involving the metaphyseal regions.


Assuntos
Pinos Ortopédicos/veterinária , Fixação Interna de Fraturas/veterinária , Fraturas Ósseas/veterinária , Animais , Fenômenos Biomecânicos , Osso e Ossos/fisiologia , Fixação Interna de Fraturas/instrumentação , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...